- Company
- Products & Services
- Technical Information
- Customer Service
- Resource Center
- Airspeed Indicators
- Altimeters
- Annunciation Control Units
- Attitude Indicators
- Autopilots
- Batteries
- Carburetor Temperature Indicators and Probes
- Clocks
- Converters
- Directional Gyros
- Emergency Locator Transmitters
- Engine Instruments
- Flex Custom Function Displays
- Frequency Converters
- Ground Power Units
- Horizontal Situation Indicators
- Installation Hardware
- Inverters
- Lighting
- Navigation Indicators
- Outlets
- Relay Units
- Standby Attitude Modules
- Transponders
- Turn and Slip Indicators
- Turn Coordinators
- USB Chargers
- Vertical Speed Indicators
- Weather Radars
- Wireless Chargers
- Airspeed Indicators
- Altimeters
- Altitude Holds, Selectors and Alerters
- Amplifiers, Power Supplies and Converters
- Annunciation Control Units
- Attitude Indicators
- Audio Panel/Marker Beacon Receivers
- Batteries
- Carburetor Temperature Indicators and Probes
- Clocks
- Computer Amplifiers
- Directional Gyros
- Emergency Locator Transmitters
- Encoders
- Engine Instruments
- Flight Computers and Controllers
- Flight Directors
- Flux Detectors
- GPS Receivers
- Horizontal Situation Indicators
- Miscellaneous Indicators
- Nav/Comms
- Navigation Indicators
- Rate Gyroscopes
- Relay Units
- Remote Gyro Systems
- Servos and Actuators
- Standby Attitude Modules
- Transponders
- Turn and Slip Indicators
- Turn Coordinators
- Vertical Speed Indicators
- Weather Radars

Custom Function Display
What’s your panel missing?
A blank slate for designers, avionics and systems engineers
Customizable configuration, user interface and graphics

Custom Dual Tachometer
Example

Custom Engine Monitor
Example

Custom G-Meter
Example

Custom Torque Indicator
Example

Custom APU Indicator
Example

Custom Cabin Entertainment Indicator
Example

Custom Cabin Pressure Gauge A
Example

Custom Cabin Pressure Gauge B
Example

Custom Lights Indicator
Example

Custom Oven Temperature Indicator
Example

Custom Triple Indicator
Example

Custom Water Level Indicator
Example
Features
- Customizable configuration (inputs/outputs), user interface and graphics
- Receives and displays ARINC 429, analog, discrete, frequency, temperature, absolute and differential pressure data
- Standard 2-inch size
- Lightweight — 0.4 lbs
- Simple user interface — Single, push-and-turn control knob
- Daylight readable LCD and smooth, high-resolution graphics
- Manual, external lighting control or built-in photocell for automatic dimming
- Field-upgradeable software and configuration via standard USB-A port
- Night Vision Imaging System (NVIS) compatible (available)
- TSO certified (Design Assurance Level A)
- Designed and built in Wichita, Kansas, USA
- Two-year limited warranty
Specifications
Power Input
10–32 VDC
0.14A @ 28 VDC; 4 watts nominal
Data Input
ARINC 429 | Low or high speed; labels per individual CID |
RS-232 | Data format per individual CID |
RS-422/485 | Data format per individual CID (-3 only) |
Analog* | 0-28 VDC, 1% accuracy (±0.050 V) (-1 and -2) |
-24-29 VDC, 1% accuracy (±0.050 V) (-3 only) | |
Discrete* | Open, ground, high |
Thermocouple | Type K (-1 and -2) |
Frequency* | 0.5-100 V pk-pk; 10-20,000 Hz (-1 only) |
Pressure | Absolute/static and differential/pitot (-2 only) |
Data Output
ARINC 429 | Low or high speed; labels per individual CID |
RS-232 | Data format per individual CID |
RS-422/485 | Data format per individual CID (-3 only) |
Analog* | 0-5 VDC, 1% accuracy (±0.050 V) (-1 and -2) |
-8-8 VDC, 1% accuracy (±0.050 V) (-3 only) | |
Discrete* | Open, ground, high |
Certification
FAA TSO certified to C2d (Type B), C3e, C4c, C8e, C10c, C106, C113b, C201
RTCA DO-160G qualified
RTCA DO-178C qualified, Design Assurance Level (DAL) A
Lighting
5, 14, or 28 VDC external control or internal photocell for automatic dimming
Battery
Rechargeable coin cell (clock memory only)
Weight
0.4 lbs (0.17 kg)
Mounting
Rear panel mounted, (4) #6–32 screws, 2.25-inch round bezel
Dimensions
2.43 x 2.43 x 1.0 inches
Mating Connector
MCIA P/N 9019162-1 26-pin, D-Sub electrical connector (Quick Disconnect)
MCIA P/N 9019162-2 Pneumatic fittings (Quick Disconnect)
Rights
U.S. Patent 11,048,389
Data Input
ARINC 429 | Low or high speed; labels per individual CID |
RS-232 | Data format per individual CID |
RS-422/485 | Data format per individual CID (-3 only) |
Analog* | 0-28 VDC, 1% accuracy (±0.050 V) (-1 and -2) |
-24-29 VDC, 1% accuracy (±0.050 V) (-3 only) | |
Discrete* | Open, ground, high |
Thermocouple | Type K (-1 and -2) |
Frequency* | 0.5-100 V pk-pk; 10-20,000 Hz (-1 only) |
Pressure | Absolute/static and differential/pitot (-2 only) |
Data Output
ARINC 429 | Low or high speed; labels per individual CID |
RS-232 | Data format per individual CID |
RS-422/485 | Data format per individual CID (-3 only) |
Analog* | 0-5 VDC, 1% accuracy (±0.050 V) (-1 and -2) |
-8-8 VDC, 1% accuracy (±0.050 V) (-3 only) | |
Discrete* | Open, ground, high |